Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
J Mol Diagn ; 23(8): 920-928, 2021 08.
Article in English | MEDLINE | ID: covidwho-1386075

ABSTRACT

The Alinity m (Abbott Molecular, Des Plaines, IL) automated molecular analyzer allows continuous loading of samples and sample-to-result molecular detection of several microorganisms. The detection of SARS-CoV-2 by the Alinity m was compared with that of the cobas 6800 (Roche Molecular Systems, Branchburg, NJ; standard comparator) in a manufacturer-independent clinical evaluation on 2157 consecutive nasopharyngeal swab samples. Valid initial results on Alinity m and cobas 6800 were obtained from 2129 (98.7%) and 2157 (100%) samples, respectively. The overall percent agreement (95% CI) was 98.3% (2092/2129 [97.6%-98.7%]); positive percent agreement, 100% (961/961 [99.6%-100%]); negative percent agreement, 96.8% (1131/1168 [95.7%-97.7%]); and high κ value, 0.965 (0.954-0.976). There were 37 discordant results on Alinity m and, based on discordant analyses, including previous and/or follow-up PCR results, 22 could be considered analytically true positive with high probability. Due to a lack of additional information and an inability to perform repeated/further testing, the status of the remaining 15 discordant results remained unresolved. The throughput of the two analyzers was compared using testing on 564 samples in parallel across two 8-hour shifts in clinical practice. The turnaround times were compared using processing of 94 routine samples in parallel on each working day for 5 consecutive days. The two analyzers showed similar performance, with certain differences that have potential importance in some laboratory settings.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , Nasopharynx/virology , RNA, Viral/genetics , SARS-CoV-2/genetics , COVID-19/virology , COVID-19 Nucleic Acid Testing/economics , Humans , RNA, Viral/analysis , Reproducibility of Results , SARS-CoV-2/isolation & purification
2.
J Clin Microbiol ; 58(6)2020 05 26.
Article in English | MEDLINE | ID: covidwho-46769

ABSTRACT

Laboratories are currently witnessing extraordinary demand globally for sampling devices, reagents, consumables, and diagnostic instruments needed for timely diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. To meet diagnostic needs as the pandemic grows, the U.S. Food and Drug Administration (FDA) recently granted several commercial SARS-CoV-2 tests Emergency Use Authorization (EUA), but manufacturer-independent evaluation data are scarce. We performed the first manufacturer-independent evaluation of the fully automated sample-to-result two-target test cobas 6800 SARS-CoV-2 (cobas) (Roche Molecular Systems, Branchburg, NJ), which received U.S. FDA EUA on 12 March 2020. The comparator was a standardized 3-h SARS-CoV-2 protocol, consisting of RNA extraction using an automated portable instrument, followed by a two-target reverse transcription real-time PCR (RT-PCR), which our laboratory has routinely used since January 2020 [V. M. Corman, O. Landt, M. Kaiser, R. Molenkamp, et al., Euro Surveill 25(3):pii=2000045, 2020, https://doi.org/10.2807/1560-7917.ES.2020.25.3.2000045]. cobas and the comparator showed overall agreement of 98.1% and a kappa value of 0.95 on an in-house validation panel consisting of 217 well-characterized retrospective samples. Immediate prospective head-to-head comparative evaluation followed on 502 samples, and the diagnostic approaches showed overall agreement of 99.6% and a kappa value of 0.98. A good correlation (r2 = 0.96) between cycle threshold values for SARS-CoV-2-specific targets obtained by cobas and the comparator was observed. Our results showed that cobas is a reliable assay for qualitative detection of SARS-CoV-2 in nasopharyngeal swab samples collected in the Universal Transport Medium System (UTM-RT) (Copan, Brescia, Italy). Under the extraordinary circumstances that laboratories are facing worldwide, a safe diagnostic platform switch is feasible in only 48 h and in the midst of the COVID-19 pandemic if carefully planned and executed.


Subject(s)
Betacoronavirus , Clinical Laboratory Techniques/methods , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , Betacoronavirus/genetics , COVID-19 , COVID-19 Testing , COVID-19 Vaccines , Humans , Pandemics , SARS-CoV-2 , Time Factors